Brand Name: WSE/WDE
Model Number: WSE/WDE
Place of Origin: Nanjing, Jiangsu, China
Product Description
MAINLY UNIT FEATURE OF SCREW COMMPRESSOR
Superior performance
- Adoption international advanced third generation 5: 6 semi-hermestic screw compressor, the motor and compressor integration, without seal leakage concerns
- Two or a plurality of compressor combination precision control program is reasonable and balanced the handpiece assembly load, prolong the service life of the unit
- Two or a plurality of compressor using multiple sets of refrigeration circuit, when a circuit must be repaired and maintenance, the remaining loop can still be operated normally, with standby function
- Compressor with duplex winding reduced-voltage starting, avoid the impact to the electric network
Easy Installation
- Compact structure, small occupation area, saving the space
- The machine has been checked ststrictly and timing operation completed to reach the using state
- Based minimum vibration, don't need the vibration isolation equipment usually, simple installation
- Just need connect with the cooling water chilled water pipe of evaporator and condenser
Low cost for operation and maintenance
- Unit can be controled by intelligent program according to the load needs: 0-25-50-75-100% volume control to save energy.
- Screw compressor has simple structure, few wearing parts, the failure rate is very low
- The built-in oil separator using three stage oil filter; Adoption the coating design to reduce the compressor'noise
- Water chiller compressor trouble-free operation over 40000 hours
Complete security protection function
- High & low pressure protection
- Anti-heatingsafety valve
- Anti freezing protection
- Overload protection,
- Incomplete phase protection
- Opposite phase protection
- lacking voltage and over voltage protection
- Water flow protection
Humanized microcomputer control system
- Adoption brand-name PLC liquid crystal color LED display, touch panel computer control, the Chinese interface for simple operation
- Automatic detect outlet temperature of chilled water system, effective tracking site load by adjusting the compressor
- The display is intuitive, can be readily read operation data for reference
- Automatic failure alarm system can display the failure code to handle
- Output feedback information to the other main control system based on the needs of field
- The original content can be modified based on the field needs, such as position of each unit, protection, pressure etc.
Application of the strong widely
- Widely used in rubber, plastic, petroleum, chemical, electronics, textile, papermaking, brew, pharmaceutical, machinery, food, beverage, vacuum coating, plating, coating, central air-conditioning and other fields
-This machine series is widely applied in the centralized cooling way
- This machine can be customized for the acid and alkali resistant special models, the special needs of customers with special process
- This machine can be customized for low temperature type special models using the low temperature cold medium, to reach the customer special technology of special needs.
Model | 100WSE | 140WSE | 160WSE | 200WSE | 250WSE | 270WSE | 310WSE | 360WSE | |
Refrigeration capacity | KW | 120 | 150 | 160 | 195 | 255 | 280 | 315 | 365 |
x10 3 KCal/hr | 103 | 129 | 138 | 168 | 219 | 241 | 271 | 314 | |
Compressor Power (KW) | 24 | 30 | 32 | 39 | 51 | 56 | 63 | 73 | |
Style | semi closed screw style | ||||||||
Start mode | Duplex winding | ||||||||
running current(A) | 40 | 52 | 56 | 66 | 86 | 94 | 105 | 133 | |
Capacity Control(%) | 0-33-66-100 | 0-25-50-75-100 | |||||||
Number of Refrigeration Circuit | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Refrigeration | R22 (Optional refrigerantion R407C) | ||||||||
Condenser | shell and tube type | ||||||||
Condenser import and outlet diameter(mm) | 60 | 76 | 76 | 76 | 89 | 89 | 108 | 108 | |
Cooling water flow(m 3 /h) | 20 | 27 | 34 | 40 | 47 | 54 | 68 | 81 | |
Evaporator | shell and tube type | ||||||||
Evaporator import and outlet diameter(mm) | 60 | 60 | 76 | 76 | 76 | 89 | 89 | 108 | |
Chilled water flow (m3/h) | 17 | 24 | 30 | 36 | 42 | 48 | 60 | 72 | |
safety protection device | High & low pressure protection,anti-freezing protection,anti-heating safety valve,overload protection,incomplete phase protection,opposite phase protection,lacking voltage and over voltage protection,water flow protection | ||||||||
Out dimension | L(mm) | 1989 | 2042 | 2313 | 2313 | 2346 | 2346 | 2596 | 2624 |
W(mm) | 661 | 729 | 729 | 793 | 863 | 890 | 890 | 950 | |
H(mm) | 1300 | 1320 | 1325 | 1330 | 1450 | 1500 | 1508 | 1600 | |
Total weight | Kg | 760 | 830 | 1020 | 1200 | 1390 | 1680 | 1890 | 1990 |
Working weight | Kg | 790 | 880 | 1100 | 1420 | 1450 | 1850 | 2103 | 2180 |
Model | 450WSE | 480WSE | 540WSE | 600WSE | 660WSE | 720WSE | 810WSE | 900WSE | |
Refrigeration capacity | KW | 455 | 485 | 540 | 605 | 689 | 731 | 811 | 924 |
x10 3 KCal/hr | 391 | 417 | 464 | 520 | 593 | 629 | 697 | 795 | |
Compressor Power (KW) | 91 | 97 | 108 | 120 | 130 | 138 | 153 | 168 | |
Style | semi closed screw style | ||||||||
Start mode | Duplex winding | ||||||||
running current(A) | 172 | 185 | 200 | 223 | 230 | 257 | 302 | 340 | |
Capacity Control(%) | 0-25-50-75-100 | ||||||||
Number of Refrigeration Circuit | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Refrigeration | R22 (Optional refrigerantion R407C) | ||||||||
Condenser | shell and tube type | ||||||||
Condenser import and outlet diameter(mm) | 133 | 133 | 133 | 133 | 159 | 159 | 159 | 159 | |
Cooling water flow(m 3 /h) | 98 | 104 | 117 | 132 | 140 | 160 | 181 | 206 | |
Evaporator | shell and tube type | ||||||||
Evaporator import and outlet diameter(mm) | 108 | 108 | 133 | 133 | 133 | 133 | 133 | 159 | |
Chilled water flow (m3/h) | 79 | 83 | 93 | 106 | 118 | 132 | 148 | 165 | |
safety protection device | High & low pressure protection,anti-freezing protection,anti-heating safety valve,overload protection,incomplete phase protection,opposite phase protection,lacking voltage and over voltage protection,water flow protection | ||||||||
Out dimension | L(mm) | 2649 | 2672 | 2932 | 2932 | 2932 | 3212 | 3419 | 3419 |
W(mm) | 990 | 1065 | 1065 | 1090 | 1090 | 1090 | 1200 | 1170 | |
H(mm) | 1685 | 1819 | 1830 | 1850 | 1850 | 1865 | 2021 | 2021 | |
Total weight | Kg | 2170 | 2290 | 2560 | 2780 | 2998 | 3189 | 3210 | 3589 |
Working weight | Kg | 2250 | 2499 | 2690 | 2990 | 3290 | 3420 | 3589 | 3890 |
Model | 200WDE | 250WDE | 270WDE | 310WDE | 380WDE | 450WDE | 540WDE | 600WDE | |
Refrigeration capacity | KW | 240 | 260 | 285 | 320 | 398 | 477 | 557 | 604 |
x10 3 KCal/hr | 206 | 224 | 245 | 275 | 342 | 410 | 479 | 520 | |
Compressor Power (KW) | 48 | 52 | 57 | 57 | 75 | 90 | 105 | 114 | |
Style | semi closed screw style | ||||||||
Start mode | Duplex winding | ||||||||
running current(A) | 81 | 105 | 108 | 113 | 134 | 174 | 191 | 216 | |
Capacity Control(%) | 0-25-50-75-100 | ||||||||
Number of Refrigeration Circuit | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
Refrigeration | R22 (Optional refrigerantion R407C) | ||||||||
Condenser | shell and tube type | ||||||||
Condenser import and outlet diameter(mm) | 76 | 89 | 108 | 108 | 108 | 133 | 133 | 133 | |
Cooling water flow(m 3 /h) | 42 | 55 | 61 | 68 | 81 | 94 | 108 | 121 | |
Evaporator | shell and tube type | ||||||||
Evaporator import and outlet diameter(mm) | 76 | 89 | 108 | 108 | 108 | 108 | 108 | 133 | |
Chilled water flow (m3/h) | 38 | 50 | 56 | 62 | 75 | 86 | 99 | 112 | |
safety protection device | High & low pressure protection,anti-freezing protection,anti-heating safety valve,overload protection,incomplete phase protection,opposite phase protection,lacking voltage and over voltage protection,water flow protection | ||||||||
Out dimension | L(mm) | 2365 | 2678 | 2678 | 2898 | 2926 | 3241 | 3274 | 3716 |
W(mm) | 875 | 970 | 970 | 970 | 1050 | 1115 | 1200 | 1240 | |
H(mm) | 1351 | 1423 | 1423 | 1470 | 1525 | 1670 | 1774 | 1899 | |
Total weight | Kg | 1499 | 1599 | 1798 | 1896 | 1910 | 2198 | 2478 | 2688 |
Working weight | Kg | 1790 | 1890 | 2098 | 2268 | 2450 | 2590 | 2689 | 2980 |
Model | 620WDE | 660WDE | 720WDE | 810WDE | 900WDE | 950WDE | 1000WDE | 1100WDE | |
Refrigeration capacity | KW | 622 | 652 | 759 | 826 | 924 | 960 | 1025 | 1100 |
x10 3 KCal/hr | 535 | 561 | 653 | 711 | 795 | 826 | 882 | 946 | |
Compressor Power (KW) | 150 | 123 | 138 | 153 | 168 | 192 | 205 | 220 | |
Style | semi closed screw style | ||||||||
Start mode | Duplex winding | ||||||||
running current(A) | 223 | 213 | 234 | 256 | 285 | 335 | 345 | 378 | |
Capacity Control(%) | 0-25-50-75-100 | ||||||||
Number of Refrigeration Circuit | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
Refrigeration | R22 (Optional refrigerantion R407C) | ||||||||
Condenser | shell and tube type | ||||||||
Condenser import and outlet diameter(mm) | 108x2 | 108x2 | 108x2 | 133x2 | 133x2 | 133x2 | 133x2 | 133x2 | |
Cooling water flow(m 3 /h) | 135 | 148 | 161 | 181 | 203 | 222 | 242 | 263 | |
Evaporator | shell and tube type | ||||||||
Evaporator import and outlet diameter(mm) | 133 | 133 | 159 | 159 | 159 | 219 | 219 | 219 | |
Chilled water flow (m3/h) | 118 | 131 | 139 | 157 | 173 | 191 | 209 | 235 | |
safety protection device | High & low pressure protection,anti-freezing protection,anti-heating safety valve,overload protection,incomplete phase protection,opposite phase protection,lacking voltage and over voltage protection,water flow protection | ||||||||
Out dimension | L(mm) | 3274 | 3176 | 3204 | 3204 | 3252 | 3884 | 3899 | 4399 |
W(mm) | 1200 | 1240 | 1400 | 1400 | 1590 | 1400 | 1490 | 1490 | |
H(mm) | 1774 | 1899 | 209 | 2125 | 2245 | 2125 | 2246 | 2246 | |
Total weight | Kg | 3168 | 3788 | 3889 | 4098 | 4208 | 4118 | 4339 | 4798 |
Working weight | Kg | 3490 | 4266 | 4398 | 4589 | 4796 | 4889 | 4786 | 4989 |
Remark: | |||||||||
1.The above power supplier is 3P-380V-50HZ,permission voltage hunting±10% ,pemission internce±2% . | |||||||||
2.The above nominal capacity is based on chilling water inlet temperature at 12°C,outlet temperature at 7 °C,cooling water temperature at 30°C,and outlet temperature at 35°C. | |||||||||
3.Equipment safe working range :Chilled water inlet temperature of 5-20ºC | |||||||||
4.This series of unit adopts imported temperature controller or PLC controllers; | |||||||||
5.If specification is changed, then the actual model shall govem. |